The X factor.If we define the relation : MU / FW = X Then X is the participation of make up at the feed water, and can vary from zero till one. The participation of condensate is: 1 - X The X is called make-up ratio, while 1 - X is condensate ratio. Operators are using the terms % make up and % condensate which correspond to: 100*X and 100*(1-X). The X factor, even being hydraulic characteristic of the process, can be calculated every moment from the chemical analysis of the water. Taking into consideration a water analysis constituent which comes into the circuit only through make-up and leaves only through blowdown and losses, is not transformed, destroyed or precipitates, like chloride ion, then its material balance for the feed water will be: MU * CLMU + C * CLC = FW * CLFW or
MU/FW * CLMU + C/FW * CLC = CLFW or
X * CLMU + (1-X) * CLC = CLFW and finally: CLFW-CLC X= ----------------- (d) CLMU-CLC
So from the water analysis of make up, feed water and condensate we can calculate the factor from equation (d). If there is not priming or carry-over, CLC=0. In any case, when:
CLC > CLMU
Condensate has to be rejected. |
|